Welcome to the Micro-CT/XRM Academy Newsletter July 2020 edition!

Covid-19 research engages Bruker’s SKYSCAN user community


Biomedical research is making a pivot toward pulmonary research to address the urgent need to know more about covid19 pneumonia, and to find means for its prevention and cure. As headlined above in our news, the group of Greetje Vande Velde at Leuven, Belgium are playing a leading role in this. The powerful lung imaging performance of skyscan in vivo microCT scanners is proving to be a key asset in the response of the global scientific community to the pandemic. Already this group have found out how the hamster – the preferred animal model for covid19 – differs from the mouse in its breathing and thus how to fine-tune the scanner and software for lung synchronised (gated) imaging. Important discoveries being made “on the fly” with fast-developing covid19 research. A description of this research can be found on Bruker's website.

In addition to research into the covid19 disease, the pandemic has created other urgent needs for scientific problem-solving such as meeting the large demand for “PPE” (personal protective equipment) including face masks. Here Bruker imaging and analytical equipment has also played a role. Bruker’s collaboration with the German company Helios helped them to innovate an effective way to sterilise face masks which hitherto had been single-use-only. This was not easy – strict standards demanded the ability to filter out submicron sized aerosols smaller than the coronavirus itself. Helios succeeded in developing a method that met these requirements for refurbishing facemasks. MicroCT imaging was used for this, performed by Markus Heneka of RJL Micro & Analytical, Bruker’s distributor in Germany and an ISO-certified laboratory. RJL used their Bruker microCT scanners to image non-destructively in 3D the critical fine membrane structure of the masks. This helped to validate the refurbishing and quality control methods of Helios. The result has been a big boost to availability of essential protective face masks.

Learn more on Bruker's website.

Finally, The new urgency of lung research means that we will also re-release the existing method note on list-mode advanced software-based image sorting, entitled: “MN 105 Image based listmode sorting for lung and cardiac in vivo”.

 
 

The new NRecon version 2.0. features phase retrieval imaging


Our July newsletter is close in time to the release of a major new version of our reconstruction software NRecon – version 2.0. This has many important new capabilities and enhancements, and one of these is phase retrieval 3D reconstruction. The phase retrieval method of Paganin (1) is one of a class of techniques termed “phase contrast”. X-ray phase contrast imaging makes use of the phenomena of refraction and diffraction of X-rays at internal boundaries of a sample, and is thus complementary to conventional absorption contrast. This is equivalent to the phase contrast imaging that is performed with visible light microscopes. Phase interactions of X-rays are of smaller magnitude than those that occur with visible light, but they are significant enough to provide the basis for realising X-ray phase contrast.

 

Paganin phase retrieval imaging


Some phase contrast methods require synchrotron radiation since they need X-rays to be of a single energy only (monochromatic) and coherent (“in step”, in the same wavetrain phase). Phase contrast methods sometimes employ precise gratings, or alternatively multiple scans of different source-camera distance, to generate the needed phase effects. This all adds to the complexity of phase contrast X-ray imaging. However, there is one phase contrast phenomenon that does happen readily in laboratory microCT systems even with polychromatic and noncoherent laboratory sources, and without the need of any gratings; this is small angle scattering. This phenomenon results in a bright “halo” surrounding object boundaries in both the projection and the reconstructed images as shown in a submicron scan of a Sorhgum plant root in figure 1. It results from the reflection of some X-rays that are incident at an object surface at a very shallow angle, much smaller than one degree.




                 (a)                                       (b)                                (c)

Figure 1. From the scan of reconstructed cross-sections of a root of Sorghum bicolor, a part of a projection image (a) and a standard reconstructed cross-section (b) show the bright edges characteristic of small angle scattering. Such bright edges indicate the potential for phase retrieval reconstruction (PR). The PR reconstruction of the same scan (c) show the conversion of the edge signal into enhanced contrast, revealing for example the higher density of a layer of peripheral cells in the root (arrow), which is not visible in the reconstruction of standard absorption based projections. Courtesy of Dr Rivka Elbaum, Faculty of Agriculture, Hebrew University of Jerusalem, Israel.


Phase retrieval (Paganin) is a method that obtains enhanced sample contrast and structural information from this small angle scattered component, and it can be realized in a single scan, not requiring multiple geometries or gratings (1). Phase retrieval is thus applicable to scans at high resolution in laboratory (including desktop) microCT scanners, and this capability has now been added to Bruker NRecon. Please note that phase retrieval is not a different CT reconstruction algorithm. It is an image processing method applied to individual 2D X-ray projection (and other) images. By applying it to a full set of scan projections, micro and nanoCT can be performed with phase retrieval.

The results of this phase retrieval applied to the sorghum root scan is also shown in figure 1 (c). The notable feature of phase retrieval imaging is the elimination of the artificial edge brightening and its conversion into enhanced contrast. Thus for example the higher density of a layer of peripheral cells in the root is shown by phase retrieval, but is not visible in the reconstruction of standard absorption based projections

 

How to perform phase retrieval in NRecon 2.0


How is phase retrieval done? Some users may be familiar with an ImageJ plugin called “Ankaphase” which performs Paganin phase retrieval on images including CT scan projections. NRecon version 2 has a similar new function which allows you to convert the full set of a scan’s projection images to their phase-retrieved counterparts. However it’s fair to say that the NRecon dialog window for doing this – shown below in figure 2 – is quite a lot simpler than ImageJ’s Ankaphase since many parameters are silently read from the scan log file. The critical parameter that you have to enter is the “delta/beta ratio” which relates to the strength of phase retrieval. One typically enters values from 100-1000, with 400-700 often being a good starting point. Other settings can – at first at least – be left at default values.

So it’s quite easy to get started with phase retrieval imaging of your own scans. High resolution scans with noticeable edge brightening are most likely to give useful results with phase retrieval; if in doubt, just try it. And since nothing additional is needed, even existing scans you have already done can be reconstructed with phase retrieval if you still have the scan projection images.

Full details of the phase retrieval method including an overview of its theory and how to do it step by step in NRecon 2.0 are given in the new method note MN133 that is linked with this newsletter, entitled: MN 133 Paganin single-distance phase retrieval reconstruction in NRecon.

Figure 2. This is the new window in NRecon 2.0 for making phase retrieval transformation of projection datasets. The main parameter to adjust is the delta/beta ratio. You process your scan’s projections using this window, with single projection preview first. The processed projections are written to a subfolder named “PR”; load and reconstruct PR cross-sections from these phase-retrieved projections, in NRecon.

 

 

References

  1. Paganin D, Mayo SC, Gureyev TE, Miller PR,  Wilkins SW (2002) Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. J. Microsc. 206, 33-40.
  2. The company collaboration between the company RJL Micro & Analytical and Helios, in German language on RJL’s website.

 
 

Volume 7, Issue 3
July 2020

 
 

News

 

A research paper hot off the press from the group of Dr Greetje Vande Velde of the Catholic University of Leuven (KUL) shows efficacy tests for hydroxychloroquine and an antiviral drug against covid19 in a hamster model using the SkyScan 1278 in vivo scanner for lung imaging.

Read more.

 

 

Scientists using SKYSCAN in vivo microCT at London's Royal Veterinary College map mechano-adaptation of the entire mouse tibia in 4D for the first time.

Read more.

 

 

Clinicians at the Massachusetts General Hospital have just published "The Role of MicroCT in Imaging Breast Cancer Specimens" in the journal "Breast Cancer Research and Treatment".

Read more.

 

 

Abstracts from the first MicroCT online “virtual rendezvous” in May are available for downloads. Fine them on Bruker's website.

 

 

 

BrukerSupport: Software Updates & Method Notes

We have pre-registered our users at BrukerSupport.com  for the distribution of documentation and software. Please log into your account and select your SKYSCAN system(s).

At BrukerSupport.com you'll find the latest software downloads available for you. In addition, the complete library of method notes has been uploaded as well.

If you did not receive an email for log-in, please apply for an account with your system serial number. Enjoy your support membership and let us know if you have any questions!


Upcoming Events

 

To help prevent the spread of COVID-19, several tradeshows and conferences have been postponed or even completely cancelled. Please follow Bruker's website closely to find the latest update: events & tradeshows.

We are committed to supporting our users constantly. If you have any questions, please feel free to reach out to us by email!

 

You have been sent this email as a valuable contact of Bruker Belgium. We take your privacy seriously and therefore updated our Privacy & Cookies Policy. You may unsubscribe from our emails at any time. 

© Copyright 2020 Bruker Belgium, a division of Bruker Corporation. All rights reserved.

Bruker Belgium | Kartuizersweg 32550 Kontich | Belgium