In this issue: New product announcements, crystal screening with M4 TORNADO, recap of IUCr 2017 Hyderabad, heart and lung cyclical imaging with SkyScan microCT, TXRF analysis of cell culture media contaminants, a golden review of DXC 2017, D2 PHASER at Mars Desert Research Station, and differentiation of mineral phases using AMICS software.
|
|
|
|
|
X-ray Diffraction & Elemental Analysis |
|
|
|
|
Innovation with Integrity
|
|
|
|
| | |
Head in the Game
|
With American football season well underway, team Bruker is proud to introduce its own line-up of new, winning instruments on the X-ray diffraction (XRD) playing field!
D2 PHASER with LYNXEYE XE-T: XRD for Everyone, Everywhere and Everything
The world’s best benchtop XRD solution, the D2 PHASER, is now available with the world’s best linear detector, the LYNXEYE XE-T. Already well known for ease-of-use, portability and high data quality, the analytical capability of the D2 PHASER can now be further extended with the unmatched intrinsic energy resolution of the LYNXEYE XE-T detector. With four times the energy resolution of traditional linear detector technology, the LYNXEYE XE-T eliminates the need for artifact-inducing K-Beta filters and inefficient secondary monochromators, resulting in increased signal and a dramatic reduction in background, leading to increased sample throughput, lower limits of detection and superior fitting results.
EIGER2 R 500K for the D8 Family of XRD Solutions
Equipped with an advanced sensor, ergonomic design and solution-level integration, the EIGER2 R 500K detector brings next generation multi-mode x-ray detection to the D8 ADVANCE and D8 DISCOVER family of XRD solutions. A monolithic sensor design with over 500,000 perfectly sized pixels, combined with an ultra-fast custom ASIC (Application Specific Integrated Circuit) results in an ideal detector for every type of measurement. The EIGER2 is the perfect match for a wide range of materials research applications, including absorber-free rocking curves and reflectometry measurements of films, rapid phase identification and quantification of powders, and advanced measurement planning and analysis routines using native 2D algorithms for texture and residual stress.
D8 DISCOVER Plus with ATLAS Goniometer and High Efficiency Turbo X-ray Source
The D8 DISCOVER has a history of pushing the boundaries of laboratory analytical x-ray instrumentation. D8 DISCOVER Plus represents the next evolution in raising the bar for top-of-the-line diffraction solutions. Building on the heritage of the traditional D8 goniometer, ATLAS takes precision to a new level while supporting the next generation of source technologies. The High Efficiency Turbo X-ray Source (TXS-HE) features a compact housing designed to tightly couple its extremely high-intensity X-ray beam with the primary optic for maximum photon capture while minimizing signal loss due to air scatter and downtime for maintenance. The capabilities of the D8 DISCOVER Plus can be further extended with the full line of D8 family optics, sample stages, and detectors, including the newly released EIGER2 R 500K.
"XE-T! EIGER2! ATLAS! Hut! Hut!" Go team, go!
|
In This Issue
|
|
|

|
The M4 TORNADO is a spatially resolving, energy dispersive X-ray fluourescence (XRF) spectrometer. It was developed for high-speed 2D elemental analysis and visualization. This lab report describes a new approach, energy dispersive Laue mapping (EDLM), where diffraction peaks, providing information about crystal orientation, are used to identify grain and twin boundaries in crystalline materials. Read More |
|
|
|
|
 |
Bruker and Incoatec's Charminar-style booth at the 24th International Union of Crystallography (IUCr) 2017 in Hyderabad, India, was the perfect place to show off our latest innovations for single crystal XRD. Comprising the new D8 VENTURE BIOTOOLS system, our IμS DIAMOND X-ray source, PHOTON III detector, and SCOUT sample-exchange robot were the hit of the conference. Read More |
|
|
|
|
 |
Movement during a micro computed tomography (microCT) scan can lead to artefacts that degrade image quality. Imaging of breathing lungs and the beating heart in live mice under anesthesia, however, is a special case where the motion cycle itself is the object of study. This article describes how to apply image-based (intrinsic) sorting of listmode scan projection images using the SkyScan Dataviewer software. Read More |
|
|
|
|

|
To ensure proper functioning of all physiological processes of cell cultures ex vivo, the natural environment of the cells must be imitated in defined media. Media often contains glucose, along with nutrient and trace elements to maintain cell health. The S4 T-STAR TXRF spectrometer can measure minute fluctuations in the composition of cell culture media, and help ensure the yield of bio-pharmaceutical product. Read More |
|
|
|
|

|
The Mars Desert Research Station (MDRS) in the Utah Desert, USA, hosts scientists studying past and future life conditions on our neighboring planet. In April 2017, a crew of 7 students from the Université Catholique de Louvain, Belgium, lived in the MDRS Habitation Module for 2 weeks. They collected geological samples from 7 locations and analyzed them with a D2 PHASER diffractometer. Their experiment established the potential of a D2 PHASER manned diffractometer someday visiting Mars! Read More |
|
|
|
|

|
This year's Denver X-ray Conference (DXC) was held July 31 to August 4 in Big Sky, Montana, USA. Bruker exhibited the newly released D2 PHASER – LYNXEYE XE-T, the S2 PUMA, and the M4 TORNADO. Providing hands-on demos on all 3 instruments to visitors, our Gold Nugget Challenge gave attendees a test sample containing predominantly "fool's gold" or real gold, and invited them to find out which theirs was! The fun continued with an ultimate prize drawing during our annual evening party. Read More |
|
|
|
|

|
This application note explains how Advanced Mineral Identification and Characterization System (AMICS) software can overcome difficulties in backscattered electron (BSE) signal segmentation to identify minerals. Minerals with similar BSE intensities, measured on a SEM in combination with a QUANTAX EDS system, could be effectively distinguished with AMICS’s unique advanced segmentation in particle mode. Read More |
|
|
|
|
|
 |
S2 PUMA overview video - Multi-element XRF analysis for all kinds of samples: cement, petrochemical, slag, geological, and yours! |
|
|

Click to enlarge
|
Volume rendered 3D image of a pharmaceutical tablet, virtually cut to visualize the internal structures. Scanned at 3µm voxel size on the SkyScan 1272. See more |
|
|
 |
If you own Bruker equipment for single crystal structure analysis, we want to hear from you! Fill out our Customer Satisfaction Survey for a chance to win a new iPad. Drawings are held twice a year and winners are announced in FIRST Newsletter. Take Survey |
|
D8 VENTURE User Wins iPad |
 |
Marco Antonio Leyva-Ramirez of Centro de Investigación y Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV) in Mexico City was the lucky winner of the first SC-XRD customer satisfaction survey lottery. "I'm very happy with our D8 VENTURE instrument. Every day it is a pleasure to work with this system and to enjoy its great technology," Leyva-Ramirez stated. In addition to his D8 ADVANCE ECO and D8 VENTURE systems, Leyva-Ramirez now has an iPad. We hope he enjoys the iPad just as much! |
|
|
 |
8-12 Oct 2017 MS&T 2017 - Pittsburgh, PA, USA, Materials Science & Technology - Visit us at Bruker Booth #618 10-12 Oct 2017 Lab Asia 2017 - Kuala Lumpur, Malaysia 15-18 Oct 2017 Investment Casting Conference & Expo 2017 - Covington, KY, USA - Join us at Bruker Booth #428 15-18 Oct 2017 TACT 2017 - Hualien, Taiwan - International Thin Films Conference 16 Oct 2017 Seminar: X-ray Fluorescence Spectrometry (XRF) - A powerful technique for the analysis of materials - Palmerston North, New Zealand 22-25 Oct 2017 GSA 2017 - Seattle, WA, USA - Geological Society of America - Come see us at Bruker Booth #625 23-27 Oct 2017 Powder XRD Workshop at PPNN - Research Centre for Nanosciences and Nanotechnology, Bandung, Indonesia 24-26 Oct 2017 The Quality Show - Rosemont, IL, USA - Visit us at Bruker Booth #1028 4-9 Nov 2017 ISTFA 2017 - Pasadena, CA, USA - International Symposium for Testing and Failure Analysis - Check us out in Bruker Booth #402 5-8 Nov 2017 Entomology 2017 - Denver, CO, USA - Entomological Society of America 5-9 Nov 2017 IUMRS-ICA 2017 - Taipei, Taiwan - International Union of Materials Research Societies, International Conference in Asia 5-10 Nov 2017 ICOTOM - St. George, UT, USA - International Conference on Textures of Materials - See us in Bruker Booth #22 12-15 Nov 2017 AAPS 2017 - San Diego, CA, USA - American Association of Pharmaceutical Scientists - Join us at Bruker Booth #2720 26 Nov - 1 Dec 2017 MRS Fall - Boston, MA, USA - Materials Research Society - Hope to see you at Bruker Booth #300-301 More Events & Tradeshows |
|
|
|
| |
© 2017 Bruker Corporation
|
Connect with us:
|
|
| |
|
|
|
|